212 860 9000 Get Free Estimate

Trine EN-850 Electric Strike, Rim Exit Device

Locksmith In New York

EN-850 Premium Electric Strike, Rim Exit Device
For use in new or replacement installation in wood or metal single door frames. Use with surface mounted rim exit device with up to 1″ throw.

FEATURES


  • EN-850 FACE PLATE – 1-5/16″ X 9″ X 3/4″
  • FAIL SECURE/FAIL SAFE: FIELD REVERSIBLE ON DC UNITS
  • ALL STAINLESS STEEL CONSTRUCTION (Stamped Mechanism and Cast Face Plate)
  • Mounting and Mechanism Holes Permit Horizontal Adjustment for Ease of Installation
  • 45ยบ FACE PLATE RAMP – Standard Feature for Deadlocking Latch and Pins
  • HOLDING FORCE – 2000 lbs. UL tested
  • DURABILITY – 1,000,000 Life cycles
  • FIELD ADJUSTABLE – Left or Right Handing In Minutes
  • CAVITY DEPTH – 1-1/4″, CAVITY HEIGHT – 1-5/8″, CAVITY WIDTH – 3/4″
  • SEMI-MORTISE TYPE – Backset 1 1/4″ deep
  • EN-LB not available for this model


STANDARDS


  • UL LISTED – 1034 Burglary Resistant Locking Mechanism for Indoor or Outdoor Use
  • BHMA – A156.5-1992, Grade 1


OPTIONAL FEATURES


  • NEW EN-LB: OPTICAL IR LATCHBOLT SENSOR AVAILABLE (See page 34 for details)
  • EN-CA: Additional coil assemblies available in all voltages listed.
  • LOW VOLTAGE BUZZER for audible signal when using DC voltage. Specify BZ-12 for 12 VDC or BZ-24 for 24 VDC.


FINISH


  • STANDARD FINISH – Satin Stainless Steel US32D
  • SATIN BRASS – US4
  • BRIGHT BRASS – US3
  • DARK BRONZE – Powder Coated
  • BRIGHT CHROME – US26

    ELECTRICAL CHARACTERISTIC CHART**


FOUR MAGNETIC COILS AVAILABLE Color coded wires depict the voltage of each coil


 

VOLTAGE


12 VAC
24 VAC
12 VDC
24 VDC

WIRE COLOR


Blue(1), Orange/White(1)
Blue(1), Black/White(1)
Orange/White(2)
Black/White(2)


 


FAIL SECURE
– NORMALLY LOCKED (Unlocked when energized) Units with AC coils are for Fail Secure (Intermittent duty) use only and should be energized for periods of less than one minute


VOLTAGE CURRENT
AMPS
OHMS SOUND DUTY

 

12 VAC .70 4.5 Buzz Intm
24 VAC .37 18.0 Buzz Intm
12 VDC .28 43.0 Silent Intm/Cont
24 VDC .15 164.0 Silent Intm/Cont

 

FAIL SAFE (Reverse Action) NORMALLY UNLOCKED (Locked When Energized) Fail safe action (continuous duty) can only operate with DC coil assemblies. Units with DC coils are field reversible, Fail Secure or Fail Safe. AC units must be changed to a DC coil for fail safe action or fail secure continuous duty operation. Strikes which are energized for periods longer than one minute need to use DC coils.


VOLTAGE CURRENT/AMPS OHMS SOUND DUTY

 

12 VDC .28 43.0 Silent Intm/Cont
24 VDC .15 164.0 Silent Intm/Cont

 

**Specify voltage when ordering

 

COMPATIBLE LOCKSETS


 

ADAMS RITE 8700-8800
AMERICAN DEVICE 4300-6300,53
APR ED22,6000
ARROW S1200, S3800, S4800, S1800
CAL-ROYAL 8000
CORBIN 29, 39, 49, ED8000, 3729, ED9200 4729, ED6200, ED7200
DOROMATIC 1590/2090, 1090
JACKSON 2095/1095
LIBERTY L2000
LOCKWOOD RC
MAGNOKROM N1900, N1500, N500/900-1
MONARCH 19-R, 18-R, 17-R, 11-R, XX-R
PARKER UL520, 505-DUR
PRECISION 101
REED 900/9100, 9200/3050, 1300/4000
RUSSWIN 372/472, ED8000, 572/736, ED9200, 635, ED6200, ED7200
SARGENT 2810, 8510, 8810/8888, 9810
TACO ED500, ED-301
VON DUPRIN 22, 33, 55, 88, 98, 99
YALE 1500/2200, 7000/7100, 7200