EN-960 Premium Electric Strike
For use in new or replacement installation in wood or metal jambs. Use with mortise exit devices, mortise locks without dead bolts and cylindrical locksets having up to 1″ throw*. For wood applications order EN-960W.
EN960 Replaces Folger Adams 310-2 3/4 Cutout
FEATURES
FACE PLATE – 1-1/4″ X 9″
FAIL SECURE/FAIL SAFE: FIELD REVERSIBLE ON DC units
ALL STAINLESS STEEL CONSTRUCTION
DURABILITY – 1,000,000 Life cycles
HOLDING FORCE – 2000 lbs. UL tested
FIELD ADJUSTABLE – Left or Right Handing In Minutes
FAIL SECURE – NORMALLY LOCKED (Unlocked when energized) Units with AC coils are for Fail Secure (Intermittent duty) use only and should be energized for periods of less than one minute
VOLTAGE
CURRENT
AMPS
OHMS
SOUND
DUTY
12 VAC
.70
4.5
Buzz
Intm
24 VAC
.37
18.0
Buzz
Intm
12 VDC
.28
43.0
Silent
Intm/Cont
24 VDC
.15
164.0
Silent
Intm/Cont
FAIL SAFE (Reverse Action) NORMALLY UNLOCKED (Locked When Energized) Fail safe action (continuous duty) can only operate with DC coil assemblies. Units with DC coils are field reversible, Fail Secure or Fail Safe. AC units must be changed to a DC coil for fail safe action or fail secure continuous duty operation. Strikes which are energized for periods longer than one minute need to use DC coils.
VOLTAGE
CURRENT/AMPS
OHMS
SOUND
DUTY
12 VDC
.28
43.0
Silent
Intm/Cont
24 VDC
.15
164.0
Silent
Intm/Cont
*1” throw based on 1/8” door gap.
**Specify voltage when ordering
EN-960 Premium Electric Strike
For use in new or replacement installation in wood or metal jambs. Use with mortise exit devices, mortise locks without dead bolts and cylindrical locksets having up to 1″ throw*. For wood applications order EN-960W.
EN960 Replaces Folger Adams 310-2 3/4 Cutout
FEATURES
STANDARDS
OPTIONAL FEATURES
FINISH
ELECTRICAL CHARACTERISTIC CHART**
FOUR MAGNETIC COILS AVAILABLE Color coded wires depict the voltage of each coil
12 VAC
24 VAC
12 VDC
24 VDC
Blue(1), Orange/White(1)
Blue(1), Black/White(1)
Orange/White(2)
Black/White(2)
FAIL SECURE – NORMALLY LOCKED (Unlocked when energized) Units with AC coils are for Fail Secure (Intermittent duty) use only and should be energized for periods of less than one minute
AMPS
FAIL SAFE (Reverse Action) NORMALLY UNLOCKED (Locked When Energized) Fail safe action (continuous duty) can only operate with DC coil assemblies. Units with DC coils are field reversible, Fail Secure or Fail Safe. AC units must be changed to a DC coil for fail safe action or fail secure continuous duty operation. Strikes which are energized for periods longer than one minute need to use DC coils.
**Specify voltage when ordering